- Power Distribution Equipment[2]
- Integrated Circuits[2]
- Electrical Contacts and Contact Materials[1]
- Counters[3]
- Flow Meters[10]
- Instrument Parts & Accessories[9]
- Other Measuring & Analysing Instruments[6]
- Pressure Sensors[5]
- Pressure Transmitters[10]
- Temperature Instruments[2]
- Testing Equipment[3]
- Alarm[2]
- Other Telecommunications Products[4]
- Contact Person : Ms. Hu Jessie
- Company Name : Nanjing Metran Measurement & Control Instrument Co., Ltd.
- Tel : 86-25-52366120
- Fax : 86-25-52899138
- Address : Jiangsu,Nanjing,No.12, Rungu Road, Guli Industrial Zone, Jiangning District, Nanjing
- Country/Region : China
- Zip : 211146
Related Product Searches:MTA/ DGA -1300 (ib) Single-Channel and Operating-End Safety Barrier,High Quality,Signal Safety Barrier, smd schottky barrier diode ss14,MTA/ DGA -1300
Safety Barrier
Functional Overview
MTA-1300 single-channel and operating-end safety barrier is a modular card loading intrinsic-safe explosion-proof instrument. It transfers the 4-20mADC signal which comes from regulator to every actuator, and restricts
dangerous energy entering into dangerous places.The isolation part adopts magnetic isolation technology,
and the measures of current limit and voltage limit. It not only improves intrinsic-safety explosion-proof function
but also increases the anti-interference ability of the system. It has been approved by the standard explosion-proof verification authority and its intrinsic-safe level is (ib)IICT6.
Technical Parameters
Input: 4-20mADC Input Channel: OneSampling Resistance: 50ΩOutput: 4-20mADC Or 1-5VDC Output Resistance: 250Ω( 1-5VDC output >500kΩ ( 4-20mADC output )Load Resistance: ≤750Ω ( 4-20mADC output, please note If you want special load resistance. 250-750Ω is available )Accuracy: ±0.2%Common-Mode Interference: when 50Hz, <5mV. Response Time: <1sThe Maximum Explosion-Proof Voltage: 220VAC or DCThe Maximum Short-Circuit Current: <30mA (Measured under intrinsic safety)The Maximum Open-Circuit Voltage: <30VDC (Measured under intrinsic safety)Zero Adjustment: ZERO potentiometer Measuring Range: SPAN potentiometer Power: 24VDC ±10%Power Consumption: <1.5WEnvironment Temperature: 0-50°CRelative Humidity: <90%RH ( non-condensing )Insulation Resistance: the power, input, output terminals≥100MΩInsulation Intensity: the power, input, output terminals1000VDC/ minuteMaintenance: Instrument can carry electricity pluggable under the condition of installation wiringWeight: about 150gIntrinsic-Safety Level: ( ib ) IICT6 Dimension: MTA:29×106×72 (width×height×depth)mmDGA:23×106×72 (width×height×depth)mmInstrument Installation: Standard 35mmDIN guiding rail car- loading installationMTA/ DGA -1300 (ib) Single-Channel and Operating-End Safety Barrier